HVAC Design, Cooling Load


Stop Guessing Pipe Sizes: Introducing the MEP Pipe Design & Sizing Handbook
A new 100-page, 20-chapter handbook for MEP/HVAC engineers covering hydronic, refrigerant, fire protection and plumbing pipe design and sizing — with formulas, worked examples, and code references.
Sep 222 min read


Stop Guessing HVAC Capacity: A Practical Cooling Load Calculation Guide
Learn the professional cooling-load workflow—from heat gains and psychrometrics to airflow, coil duty and equipment selection—with a practical 157-page HVAC guide.
Sep 167 min read


Sizing a Packaged AC Unit Is Not That Difficult—If You Know the Correct Procedure
Correct package-unit sizing is not simply a conversion from floor area to tons. Follow this practical procedure to check cooling load, airflow, humidity, fan pressure and corrected equipment performance.
Aug 2913 min read
How to Place HVAC Air Terminals Correctly
Correct air-terminal placement is not a matter of drawing diffusers at equal distances. Learn how to position supply, return and exhaust devices using the room load, required airflow, tested throw, occupied-zone comfort, contaminant control and commissioning checks.
Aug 2917 min read


Cooling Load Calculation: A Practical HVAC Design Guide from Building Data to Equipment Selection
Master HVAC cooling load calculations from building data to equipment selection. This practical guide covers heat transfer, psychrometrics, envelope and internal loads, ventilation, airflow, coil duty, equipment selection, worked examples, and common design mistakes—ideal for HVAC engineers, MEP designers, consultants, contractors, and students.
Aug 1611 min read


🔇 How to Select HVAC Sound Attenuators Without Excessive Pressure Loss
Learn how to select HVAC sound attenuators that effectively control noise without creating excessive pressure loss. This practical guide covers insertion loss, octave-band performance, face velocity, regenerated noise, attenuator sizing, installation considerations, and fan ESP—helping engineers achieve quieter, more energy-efficient HVAC systems.
Aug 151 min read


How to Design Vertical Refrigerant Risers and Oil Traps
A practical guide to designing vertical refrigerant risers and oil traps, covering oil return velocity, suction pressure drop, trap placement, double risers, liquid line lift, and key commissioning checks for reliable DX and VRF system performance.
Aug 82 min read


Refrigerant Pipe Sizing: Velocity, Pressure Drop & Oil Return
Refrigerant pipe sizing is not only about selecting a pipe that “fits.”A wrong pipe size can reduce cooling capacity, increase compressor load, create noise, and even affect compressor reliability. Why pipe sizing matters ✅ Maintains proper refrigerant flow ✅ Controls pressure drop ✅ Supports oil return to the compressor ✅ Protects cooling capacity ✅ Reduces noise and vibration ✅ Improves long-term system reliability Main refrigerant lines 🔵 Suction Line Carries low-pressure
Aug 81 min read


AHU Casing Leakage & Thermal Bridging
AHU casing leakage and thermal bridging can reduce delivered airflow, increase fan and cooling energy, create condensation risk, and affect comfort. This article explains the causes, performance impact, inspection points, and practical ways to improve AHU casing performance.
Aug 81 min read


UV-C Systems Inside AHUs: Design Benefits and Limitations
UV-C systems inside AHUs can help keep cooling coils, drain pans, and wet surfaces cleaner by reducing biofilm and microbial growth. This article explains the design benefits, correct installation locations, BMS points, safety requirements, maintenance needs, and key limitations engineers must consider.
Aug 81 min read


💧 Selecting Moisture Eliminators for High-Velocity Cooling Coils
High-velocity cooling coils can carry condensate into downstream ducts, filters and equipment. This guide explains how to select moisture eliminators using coil face velocity, droplet-removal efficiency, pressure drop, drainage capacity, materials and maintenance requirements. It also includes calculation methods, a worked example and practical commissioning checks.
Aug 52 min read


How Dirty Filters Change Airflow, Fan Power and Cooling Capacity
Dirty filters are more than a maintenance issue. They increase pressure drop, reduce airflow, affect fan power, lower cooling capacity and can cause humidity, DX coil freezing and low delta-T problems in HVAC systems.
Aug 52 min read