Pump Head in Metres vs kPa: Keep the Fluid-Density Basis Visible

Oct 15
4 min read
Original paired gauge illustration showing 235.36 and 244.77 kilopascals at the same 24 metre head for assumed liquid densities of 1000 and 1040 kilograms per cubic metre.

A pump schedule lists 24 m head, a coil schedule lists pressure drop in kPa, and a test instrument displays metres of water column. Those numbers can be compared, but their unit labels carry different meanings. The density of the pumped liquid belongs in the conversion between pressure and actual liquid head. A conventional water-column pressure unit already has a defined pressure value.


This distinction becomes important when reviewing a liquid other than the original reference water. A higher pressure reading does not necessarily indicate more pump head, and an unchanged head duty does not necessarily mean unchanged pump power. Make the basis visible before comparing selections or applying a correction factor.


1. Write the pressure-to-head relationship with units


For a pressure difference represented as equivalent liquid head, Δp = ρgH. With density ρ in kg/m³, gravity g in m/s² and head H in metres of that liquid, the pressure difference is in Pa. Therefore ΔpkPa = ρgH/1,000 and H = 1,000ΔpkPa/(ρg).


Grundfos' pump-curve explanation gives this conversion. It is a unit-and-fluid relationship, not an instruction to multiply every head figure by specific gravity. For actual pump measurements, elevation and velocity-head differences must also be included when relevant; this article assumes they cancel between the comparison sections.


Use g = 9.80665 m/s² throughout the following examples. The two illustrative densities are 1,000 and 1,040 kg/m³. They are assumed values for demonstrating the basis change, not specifications for a particular glycol concentration or temperature.


2. Compare the same head in two liquids


Suppose a centrifugal pump provides 24.00 m head at 30.0 m³/h for each of two hypothetical liquids. Hold rotational speed, impeller, viscosity effects and efficiency unchanged for this density-only comparison. It is an assumed common duty point, not a prediction that every real fluid substitution preserves the duty.


For liquid A at 1,000 kg/m³, pressure rise is 1,000 × 9.80665 × 24/1,000 = 235.36 kPa. For liquid B at 1,040 kg/m³, it is 1,040 × 9.80665 × 24/1,000 = 244.77 kPa. The head is identical; pressure rise is 4% greater because density is 4% greater.


Conversely, suppose the required differential is a fixed 240.0 kPa. Its equivalent head is 240,000/(1,000 × 9.80665) = 24.473 m for A, and 240,000/(1,040 × 9.80665) = 23.532 m for B. A fixed pressure requirement and a fixed head requirement are different comparison conditions.


This matters when a selection chart has a pressure axis derived for reference water. Convert the requested duty using the actual liquid basis before placing it on a head curve. If software already applies the selected density to its displayed kPa axis, another manual density correction would change the duty twice.


3. Distinguish actual liquid head from a pressure display


An instrument label such as mH₂O can denote a pressure unit expressed as an equivalent water column. It does not automatically mean metres of the liquid currently flowing through the pump. Check the instrument's unit definition and configured reference density or reference temperature.


NIST's SI conversion tables distinguish conventional water-column units from temperature-specific water-column definitions. Using the conventional definition, 1 mH₂O corresponds to 9.80665 kPa. Thus a displayed 10.00 mH₂O represents 98.0665 kPa.


For liquid B, the actual liquid head equivalent to that pressure is 98,066.5/(1,040 × 9.80665) = 9.6154 m. Reporting the display directly as 10.00 m of liquid B would overstate its pressure-head contribution. Conversely, an actual 10.00 m head in liquid B corresponds to 101.989 kPa, or 10.40 conventional mH₂O.


Record both the raw display unit and the converted result. Avoid abbreviating all three quantities as “metres”: actual liquid head, conventional water-column pressure and temperature-referenced water-column pressure should remain identifiable in the calculation.


4. Check whether a pressure-loss figure was already corrected


Consider a purely resistive pipe segment at a fixed volume flow. Write its loss as Δp = Kρv²/2, where K includes the applicable straight-pipe and local resistance terms. If geometry, velocity and resistance coefficients are held fixed, pressure drop scales with density while head loss Δp/(ρg) remains unchanged.


For an original assumed loss of 150.0 kPa in liquid A, the density-only result in B is 156.0 kPa. The head loss is 15.2957 m for either liquid. The 4% increase belongs in pressure; multiplying the 15.2957 m head by 1.04 as well would double-count density in this simplified comparison.


The qualification about resistance coefficients is essential. Real fluid changes may alter viscosity, Reynolds number and component performance. A manufacturer's coil or valve pressure drop already stated for the actual mixture should not receive another generic density multiplier. Conversely, a water-only figure needs the appropriate equipment-specific correction before being treated as actual-fluid loss.


Grundfos' density-and-viscosity guidance directs the user to configure the actual medium in pump sizing. Use the final liquid-rated selection to establish the real curve and duty, rather than extending this density-only exercise into a complete glycol redesign.


5. Keep the power comparison on the same boundary


At the assumed common duty of 30.0 m³/h and 24.00 m, volume flow is 30/3,600 = 0.0083333 m³/s. Hydraulic power is Ph = ρgVH, or equivalently Δp × V. Pressure in kPa multiplied by volume flow in m³/s gives power in kW.


For A, hydraulic power is 235.3596 × 0.0083333 = 1.9613 kW. For B, it is 244.773984 × 0.0083333 = 2.0398 kW. With an assumed pump efficiency of 75% in both cases, shaft inputs are 2.6151 and 2.7197 kW. Both rise by 4% in this deliberately isolated comparison.


These shaft values are not electrical meter readings. KSB's pump power-input definition places that input at the shaft or coupling. Motor and drive losses require separate treatment. Retain the manufacturer's selected-fluid power curve and required operating range when checking the actual drive selection.


At the same 24 metre head and 30 cubic metre per hour flow, assumed densities of 1000 and 1040 kilograms per cubic metre give pressure rises of 235.36 and 244.77 kilopascals. A separate 10 conventional metre-water-column display equals 9.6154 metres of the denser liquid.

Original density-only comparison with g = 9.80665 m/s². The common head and efficiency are assumed; viscosity and actual equipment performance require a liquid-rated selection.


6. Leave a clear basis trail


  • State the liquid, concentration basis where applicable, temperature and density source.

  • Label every loss as actual-fluid kPa, actual-liquid head, or a defined pressure unit.

  • Identify corrections already applied by a supplier, instrument or calculation tool.

  • Compare head, flow and power at the same operating condition.

  • Obtain revised fluid-rated performance when viscosity or other fluid properties change materially.


The paid Pump Head Calculator Design Suite v1.0 provides an editable Excel workflow with head outputs in metres and kPa and pump-pressure and power estimates. Use it to keep the head calculation reviewable, with the fluid basis and supplier corrections documented alongside the inputs. Consistent units make the comparison meaningful before any equipment decision follows.