HVAC Design
Practical HVAC design guidance, calculations, and engineering workflows.


Ventilation Purge Time: Calculate Concentration Decay Above Outdoor Background
One nominal air change leaves a substantial fraction of an initially well-mixed tracer behind. Calculate the decay above background and state the limits before using a purge time.
Oct 165 min read


Diffuser Throw at VAV Minimum: Read the Catalog at the Actual Airflow
A diffuser can pass the peak-flow schedule yet need a closer review at occupied minimum flow. Keep airflow, terminal velocity, temperature and mounting assumptions together.
Oct 165 min read


Duct Leakage at Operating Pressure: Convert Each Tested Section Before Adding
A leakage test and an operating airflow balance describe different conditions. Translate each section to its own pressure before estimating the combined loss.
Oct 165 min read


Duct Heat Gain at Low Airflow: Calculate the Supply-Air Temperature Rise
A lower airflow can leave a duct warmer even while the total heat gain falls. A simple exponential heat balance shows why terminal supply temperature deserves a turndown check.
Oct 155 min read


Valve Cv vs Kv: Reconcile the Coefficient and the Gallon Before Comparing
Two different coefficient numbers may describe the same valve capacity. Reconcile flow units, differential-pressure units and the stated gallon convention first.
Oct 154 min read


Cooling-Coil Water Velocity: Count Parallel Circuits Before Dividing Flow
Total coil flow does not reveal the velocity inside a tube. A circuit-count example shows why the same tube bank can have different hydraulic duties.
Oct 154 min read


Cooling-Coil SHR: Check Sensible and Latent Capacity at the Same Conditions
Total cooling capacity can exceed the requirement while moisture removal still falls short. Convert SHR into two capacity checks and request the operating points that matter.
Oct 155 min read


Pump Head in Metres vs kPa: Keep the Fluid-Density Basis Visible
A 24 m pump duty can represent different pressure rises for different liquids. Keep actual liquid head, water-column pressure units and power on consistent bases.
Oct 154 min read


Return-Air Lighting Heat: Separate Room Load from Cooling-Coil Load
Heat captured directly by the return-air path can bypass the room-air load while still reaching the cooling coil. Track its destination and timing before selecting airflow or capacity.
Oct 145 min read


Cooling-Coil Face Velocity: Use Active Finned Area, Not AHU Envelope
The AHU’s outside width and height can make a cooling coil look slower than it is. Use the finned face and the airflow actually passing through it.
Oct 144 min read


Control-Valve Position Is Not Flow: Read the Equal-Percentage Characteristic
A valve trend at 50% does not establish half design flow. Check what the point represents, then apply the selected characteristic and measured valve pressure drop.
Oct 144 min read


AHU Fan Stability: Check Clean- and Dirty-Filter Operating Points
A fan can satisfy the clean and dirty design duties yet fall outside its recommended range at reduced airflow. Review the whole operating envelope on the selected curves.
Oct 144 min read