HVAC Design
Practical HVAC design guidance, calculations, and engineering workflows.


HVAC Fans in Series: Add Pressure at Equal Flow, Then Recalculate the Duty
Two fans in the same flow path change the available pressure curve. A transparent numerical example separates that curve from the airflow the complete system actually delivers.
Oct 244 min read


AHU Temperature Traverses: Weight Each Reading by Airflow Before Calculating Load
A cold patch and a warm patch do not contribute equally when their airflows differ. Preserve paired velocity and temperature readings before reducing an AHU traverse to one number.
Oct 244 min read


AHU Cooling-Coil Circuiting: Why Equal UA Does Not Guarantee Equal Capacity
The flow arrangement belongs in a cooling-coil calculation. A checked dry-coil example shows how equal conductance can produce different capacities and misleading inferred UA values.
Oct 235 min read


Steam Humidification in an AHU: Include Steam Enthalpy in the Leaving-Air Temperature
Steam addition changes humidity ratio and air enthalpy together. Follow an original mass-and-energy balance to distinguish humidifier duty from the small dry-bulb rise.
Oct 235 min read


Parallel AHU Filters: Calculate Flow Redistribution When Bank Resistances Differ
A bank delivering its scheduled total airflow can still send too much air through individual filters. Solve equal pressure drop and total flow together before accepting a mixed-resistance bank.
Oct 235 min read


AHU Sensor Time Alignment: Separate Air-Transport Delay from Sensor Lag
Two temperature readings with the same timestamp may describe different air histories. Separate travel time, sensor response and logging delays before diagnosing an AHU from a transient.
Oct 235 min read


AHU Air Leakage After the Cooling Coil: Quantify the Hidden Moisture Load
Humid air entering after the cooling coil misses the intended dehumidification process. A dry-air mass balance shows how a modest leak can exceed the supply-moisture limit.
Oct 225 min read


Multi-Zone AHU Ventilation: Recheck Critical-Zone Efficiency at Part Load
A lower AHU supply volume can coincide with a higher calculated outdoor-air intake. Check the critical zone and the system airflow together rather than carrying one design efficiency into every operating case.
Oct 225 min read


AHU Vibration Isolation: Check Spring Deflection at the Lowest Operating Speed
An isolator that performs well at full fan speed can transmit much more force at turndown. Check the actual loaded spring deflection against the complete operating-speed range.
Oct 225 min read


AHU Outdoor-Air Fraction from Temperatures: Check the Uncertainty Before Trusting the Result
The same calculated 25% outdoor-air fraction can mean very different things. Quantify the temperature-error range before adjusting a damper or accepting a ventilation result.
Oct 225 min read


Wraparound Heat Pipes: Separate Coil Duty from Recovered Heat
A four-state heat balance shows why wraparound precool and reheat cannot be counted twice, and why cooling-coil duty differs from cooling delivered to rooms.
Oct 215 min read


Dry Cooling-Coil UA Trending: Separate Temperature Driving Force from Deterioration
A lower cooling-coil kW reading does not establish deterioration. Normalize the driving temperature and confirm both flows before using an apparent UA trend.
Oct 215 min read