HVAC
Practical HVAC design, equipment, controls, energy and refrigerant guidance.


Warehouse HVLS Fans: Verify Occupied-Zone Airspeed and Coverage
A warehouse-wide average can conceal stagnant packing stations and excessive airspeed in another aisle. Define the occupied footprint, test the real layout, and report who actually receives the intended air movement.
Oct 114 min read


Supply–Return Airflow Tracking: Why a Fixed Offset Does Not Guarantee Building Pressure
The supply–return difference must cover local exhaust before any surplus can leave through the envelope. A fixed offset can remain on target while building pressure changes substantially.
Oct 104 min read


HVAC Trend Sampling and Sensor Response Time: Avoid Aliasing a Hunting Control Loop
A smooth BAS graph can hide a fast oscillation, and a slow-looking cycle may be an alias. Check the entire measurement chain before changing controller settings.
Oct 104 min read


Estimating Chilled-Water Bypass Flow from Temperature Mixing
Temperature mixing can reveal bypass-flow fractions in a primary-secondary plant. Two worked examples show the calculation and where field measurements can mislead.
Oct 104 min read


Pump Impeller Trimming vs VFD Speed Reduction: Where Affinity Laws Need Care
An impeller trim and a speed change can produce similar preliminary numbers while requiring different evidence. Check the full curve before committing to either.
Oct 104 min read


AHU Condensate Rate: Calculate Drain Volume from Humidity Ratio
A drain-volume check can reveal unit mistakes, changing moisture loads and collection problems. Start with dry-air mass, then separate steady moisture removal from water stored in the coil and pan.
Oct 104 min read


Duct Expansion Transitions: Angle, Static Recovery and Total-Pressure Loss
A widening duct can gain static pressure while still losing total pressure. Calculate both before assigning a benefit to a longer transition or crediting recovery in the fan calculation.
Oct 104 min read


Chilled-Water Pipe Bore: Why Nominal Size Can Understate Pressure Loss
A nominal pipe-size label does not define the waterway. Check the submitted wall schedule and actual bore before accepting a chilled-water pressure-loss calculation.
Oct 94 min read


Control-Valve Authority: Track the Changing Pressure Boundary
A valve-authority number needs a declared circuit and operating condition. Separate design resistance ratio from changing branch differential pressure before diagnosing poor modulation.
Oct 94 min read


Pump Wire-to-Water Efficiency: Reconcile Logged kW and Hydraulic Duty
Build a defensible pump-efficiency trend using synchronized hydraulic and electrical measurements, a clear meter boundary and energy-weighted logging.
Oct 94 min read


Rectangular Duct Diameter: Hydraulic or Equal-Friction Equivalent?
Hydraulic diameter and equal-friction equivalent diameter preserve different relationships. Follow one calculation method consistently and use the real duct area for velocity.
Oct 94 min read


Duct Insulation Takeoff: Separate Surface Area from Wrap Cutting Length
A duct surface quantity does not equal the blanket quantity to order. Use external dimensions, product-specific stretch-out rules and a separate fitting schedule to build an auditable insulation takeoff.
Oct 94 min read